配管的技术要求
Technical requirements for piping
1、线管配线有明配和暗配两种:明配管要求横平竖直、整齐美观;暗配管要求管路短,畅通、弯头少。
1, the line pipe wiring has two kinds of matching and dark matching: the Ming pipe requires vertical vertical, neat and beautiful, dark piping requires short pipeline, smooth, less elbow.
2、按设计图选择管材种类和规格,如无具体要求时,可按线管内所穿导线的总面积(连外皮),不超过管子内孔截面积的70%的限度进行选配。
2, according to the design chart, choose the type and specification of pipes. If there is no specific requirement, it can be selected according to the limit of the total area of the traverse in the line pipe (even the outer skin) and the limit of 70% of the inner hole section area of the pipe.
3、为便于管子穿线和维修,在管路长度超过下列数值时,中间应加装接线盒或拉线盒,其位置应便于穿线:
3. In order to facilitate the pipe line and maintenance, when the length of the pipe is more than the following value, a junction box or a wire box should be installed in the middle, and its position should be easy to wear.
a、管子长度每超过40米,无弯曲时;b、长度每超过25米,有一弯时;c、长度每超过15米,有两个弯时;d、长度每超过10米,有三个弯时。
More than 40 meters per a, the length of the pipe, without bending; more than 25 meters, the length of each B, there is a more than 15 meters; each C and the length of two corners; more than 10 meters, the length of each D, there are three corners.
4、线管的固定:线管在转弯处或直线距离每隔1.5米应加以固定。
4, the fixed line tube: the line pipe should be fixed at the turn or straight distance every 1.5 meters.
5、电缆线管的弯曲半径应符合所穿入电缆弯曲半径的规定(电缆性质、种类不同要求不同)。6、所用线管无砂眼、裂缝和较大变形且管内壁光滑无毛刺避免线缆损伤。
5, the bending radius of the cable tube should be in accordance with the provisions of the bending radius of the cables (the nature of the cable, the different types of requirements). 6, use the line pipe no blisters, cracks and large deformation and the inner wall of the pipe is smooth without any burr to avoid the cable damage.
7、线管的连接采用管接头压接或顶接。
Connect 7, line pipe using crimping or connecting pipe joint.
8、竖直敷设的线管,按穿入导线截面的大小,在每隔10米处,增加一个固定穿线的接线盒(拉线盒),用绝缘线夹将导线固定在盒内。导线越粗,固定点之间的距离越短。
8, the vertical laying of the line pipe, according to the size of the wire cross section, at every 10 meters, add a fixed wiring junction box (pull box), with insulated wire clamp to wire fixed in the box. The thicker the wire, the shorter the distance between the fixed points.
9、在不进入盒(箱)内的垂直管口,穿入导线后,应将管口作密封处理。
9, in the vertical pipe which does not enter the box (box), after entering the wire, the pipe mouth should be sealed.
10、接线盒或拉线盒的固定应不少于三个螺丝,接线盒或拉线盒应加盖封闭,线管的分支处应加设分线盒便于检查和操作。
10, the fixing of the junction box or the pull box should be not less than three screws. The junction box or the pull box should be sealed. The branch line should be equipped with a distributing box for inspection and operation.